Welch · Physics
AP Physics C/ECE1401 · Physical inquiry

Thermal mixing & calorimeter calibration

Guided laboratory with student-chosen procedure details, repeated physical measurements, model predictions, propagated uncertainty, and a complete web-based report. Save or print to PDF.

coolwarmmix & measureT finalinsulated cup reduces transfer to room
Treat both samples and the container as one system, then check whether energy transfers balance within uncertainty.

Purpose, apparatus, method and measurements

Safety: Use ordinary warm tap water below approximately 50°C, not boiling water. Avoid glass if possible; wipe spills immediately. Handle thermometers carefully. Do not use chemical additives or heating elements in the student setup.

Question and physical prediction

How closely can an insulated water-mixing experiment obey a first-law energy balance? Can residual differences estimate the cup's effective heat capacity? Measure initial and final temperatures and both water amounts, repeating three controlled trials.

Tideal=(mhTh+mcTc)/(mh+mc)
Ccup = c[mh(Th−Tf)/(Tf−Tc)−mc]

Apparatus and controls

Two cups, one insulated mixing cup with lid, basic thermometer, measuring cylinder or kitchen scale, room-temperature water and warm tap water. The cup begins at the cool-water temperature; record any observed departure. Measure both sample masses (or assume 1 mL water ≈ 1 g, noting the approximation). Mix promptly, cap, stir gently, and record a stable final temperature. Use a fresh setup for each trial.

Measured data: kg and °C

TrialmhotThotmcoldTcoldTfinal
1
2
3

How to read the new graph: Each measured equilibrium temperature is plotted against the ideal water-only prediction. The reference line represents agreement; signed residuals are measured minus predicted. A systematic offset can indicate cup heat capacity or heat loss. The graph updates only from the measurements you enter.

Enter measured data, then calculate.

Required reasoning

Write the insulated energy balance and derive the no-cup prediction. Infer a cup heat capacity under the stated assumptions; do not claim cup heat capacity is known independently. Propagate uncertainty using partial derivatives or sensitivity coefficients. Separate thermometer calibration, transfer loss and container absorption.

Scientific report